Electric Meter Sockets & Service Entrance Masts

In Coastal Virginia, utility ownership stops at the weatherhead drip loop or underground meter lugs—meaning the meter socket, riser mast, and service entrance cable belong to the property owner. We replace rusted coastal meter jaws, storm-bent masts, and multi-family meter banks with same-day Dominion Energy reconnects.

Six-position horizontal electric meter socket trough feeding five exterior General Electric load centers and main enclosure on brick wall
Pricing & Service Overview • Hampton Roads (757)

Who repairs a rusted electric meter box or storm-pulled weatherhead in Hampton Roads?

Dominion Energy maintains utility lines up to the weatherhead splice or underground line lugs, while a licensed Master Electrician must repair or replace the meter socket enclosure, service mast, weatherhead, and load-side conductors. Scott's Electric LLC replaces 200A/400A ringless meter bases and multi-gang meter troughs across all 7 cities, securing municipal inspection release for same-day utility re-energization.

Single 200A Meter Base
$950 – $1,850 Turnkey
Mast & Weatherhead
Rigid Galvanized / Schedule 80 PVC
Multi-Unit Troughs
2-Gang to 6-Gang+ Meter Banks
Utility Standard
Dominion Energy Blue Book Compliant
Anti-Oxidant Spec
Noalox Lug Termination Compound
24/7 Emergency Line
(757) 536-0478
Credentials: Virginia Master Electrician — Licensed & Insured VA Class A Contractor
Call 24/7 Dispatch: (757) 536-0478 →
NEC & VIRGINIA USBC ENGINEERING STANDARDS

Code-Compliant Materials & Technical Execution

DOMINION BLUE BOOK

200A & 320A/400A Lever-Bypass & Ringless Bases

We install Dominion Energy approved ringless meter sockets (and commercial lever-bypass sockets required on 320A/400A and commercial services) leveled on masonry or siding with stainless hardware and watertight hubs.

NEC 230.28

Storm-Rated Rigid Conduit Masts & Guying

Overhead utility triplex drops exert heavy tension during coastal winds. When risers penetrate roof eaves, we install heavy-wall Rigid Metal Conduit (RMC) with neoprene flashing boots, porcelain/insulated clevises, and proper drip loops.

NEC 230.85

Exterior Meter-Main & Multi-Family Disconnects

For multi-unit properties and NEC 2020/2023 service upgrades, we install horizontal meter troughs feeding grouped NEMA 3R exterior main-breaker disconnects and dual copper grounding electrode rods.

Step-by-Step Electric Meter Base, Service Mast & Weatherhead Repair Process in 757

STEP 01

Utility Cut & Safety Tag

Coordinate morning disconnect with Dominion Energy (or immediate emergency cut after storm damage).

STEP 02

Socket, Riser & Grounding Install

Mount new NEMA 3R meter base, pull 4/0 copper or aluminum SEU/conduit conductors with Noalox, and drive dual 8-ft ground rods.

STEP 03

Municipal White-Card Inspection

Meet city electrical inspector to verify grounding, bonding, and Dominion Blue Book clearances for immediate utility release.

STEP 04

Same-Day Meter Set & Power-Up

Verify phase-to-phase 240V and phase-to-neutral 120V balance under household load once re-energized.

100% Real Jobsite Proof

Verified Electric Meter Base, Service Mast & Weatherhead Repair Field Work

Unretouched Hampton Roads jobsite photography documented by our licensed Virginia Master Electricians.

Call 24/7: (757) 536-0478
Open four-jaw exterior electric meter base leveled on brick masonry with load-side aluminum conductors landed and Noalox anti-oxidant compound

Exterior Meter Socket Leveled On Brick

New four-jaw ringless exterior utility meter socket anchored level to brick masonry with load-side aluminum conductors terminated on the lower jaws and Ideal Noalox anti-oxidant compound staged atop the enclosure.

Open NEMA 3R outdoor Eaton 200-amp main breaker panel mounted on siding with phase-taped service loops and PVC conduit

Exterior NEMA 3R Eaton 200A Service Panel

Outdoor NEMA 3R Eaton 200A main-breaker service panel mounted on exterior lap siding with phase-identified service entrance loops, bonded neutral bar, and lower PVC conduit entry.

Open NEMA 3R Square D Homeline 200-amp exterior main-breaker panel on vinyl siding with top service feeders and NM-B branch circuits

Exterior NEMA 3R 200A Homeline Loadcenter

Exterior NEMA 3R Square D Homeline 200A main-breaker loadcenter mounted on horizontal siding with dead-front removed, showing top-fed service conductors and orange 10 AWG and white 14 AWG NM-B branch cables routed down the side gutters.

Instant Estimate & Panel Load Check

Estimate Any Repair or Upgrade

Skip Form — Call (757) 536-0478
Preliminary Turnkey Range (Virginia Beach, VA)$1,800 – $2,250Includes licensed Master Electrician labor, NEC code materials & municipal permit coordination
Confirm by Phone: (757) 536-0478
Common Questions

Electric Meter Base, Service Mast & Weatherhead Repair Cost, Code & Permit FAQs

Straight answers from our licensed electricians — or call (757) 536-0478 anytime.

Q. Does Dominion Energy replace rusted electric meter boxes in Virginia Beach or Norfolk?

No. Dominion Energy owns the plug-in smart meter glass/module itself, while the homeowner or commercial building owner is responsible for the metal meter socket enclosure, jaws, riser conduit, weatherhead, and service entrance cable.

Q. How fast do coastal meter boxes corrode near Oceanfront, Chic's Beach, Ocean View, and Buckroe Beach?

Salt spray within 1–2 miles of the Chesapeake Bay or Atlantic Ocean can rust standard painted steel meter enclosures and pit internal copper/tin meter jaws in 10–15 years—causing overheating, flickering lights, or melted meter lugs.

Q. What is a 'White Card' or electrical cut-in release in Hampton Roads?

Before Dominion Energy will reconnect power to a replaced meter base or storm-repaired weatherhead, the city's electrical inspector must transmit an electronic/white-card inspection release confirming the installation meets NEC and Virginia USBC safety standards. We handle the entire permit and release workflow.

Q. Can you upgrade a duplex or apartment building's multi-meter bank?

Yes. We replace aging multi-gang meter stacks with horizontal UL-listed meter troughs feeding individual exterior NEMA 3R tenant disconnects with permanent unit labeling.

Q. Should I replace frayed cloth-covered SEU cable running down the side of my house?

Yes. Once UV sunlight cracks the gray outer jacket of older cloth/braided Service Entrance (SEU) cable, rainwater wicks directly down inside the cable jacket into your meter jaws and indoor breaker panel—accelerating busbar rust and short circuits.

24/7 Dispatch: (757) 536-0478